Gamatronic Electronic Industries Ltd. x POWER+ 3x208 V User Guide, Release 2.3 Figure 206: Level 1 password access...
Gamatronic Electronic Industries Ltd. 84 POWER+ 3x208 V, User Guide, Release 2.3 7. Use the arrow keys to set BAT-HI, press Ent, and then Esc: [Mai
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 85 4. Select UNDER TEMPERATURE: [Main Menu > SETUP > (password) &
Gamatronic Electronic Industries Ltd. 86 POWER+ 3x208 V, User Guide, Release 2.3 2. Use the arrow keys to set the integration factor alarm value—pre
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 87 8.9 “Setup – Module Conf.” Option 1) Num of phase2) Module/s frequen
Gamatronic Electronic Industries Ltd. 88 POWER+ 3x208 V, User Guide, Release 2.3 2. Select Module conf.: [Main Menu > SETUP > (password) >
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 89 8.9.3 Setting Module/s Voltage 1. Select Module/s voltage: [Main Me
Gamatronic Electronic Industries Ltd. 90 POWER+ 3x208 V, User Guide, Release 2.3 8.9.5 Output Adjustment 1. Select Output Adjust: [Main Menu > S
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 91 8.9.6 Setting Frequency Limits 1. Select Frequency Limits: [Main Me
Gamatronic Electronic Industries Ltd. 92 POWER+ 3x208 V, User Guide, Release 2.3 3. Adjust the measured value using the arrow keys, and press Ent to
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 93 8.10 “Setup – Battery” Option 1) Test-Voltage2) Test Alarm3) Current
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 xi Figure 258: Setting an IP address...
Gamatronic Electronic Industries Ltd. 94 POWER+ 3x208 V, User Guide, Release 2.3 1. To enter Setup, use the default password <<<<<<
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 95 8.10.2 Setting Battery Test Voltage Alarm 1. Select Test Alarm: [Ma
Gamatronic Electronic Industries Ltd. 96 POWER+ 3x208 V, User Guide, Release 2.3 8.10.3 Setting Battery Current Limit 1. Select Current-Limit..: [M
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 97 8.10.4 Enable/Disable Battery Current Limit 1. Select Current-Limit.
Gamatronic Electronic Industries Ltd. 98 POWER+ 3x208 V, User Guide, Release 2.3 8.10.5 Setting Temperature Compensation 1. Select Temp Compensat.:
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 99 8.10.6 Setting Disable Temperature Compensation 1. Select Temp Compe
Gamatronic Electronic Industries Ltd. 100 POWER+ 3x208 V, User Guide, Release 2.3 2. Select Set absolute minimum output voltage: [Main Menu > SET
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 101 8.10.8 Activating the Battery Test 1. Select Battery test…: [Main
Gamatronic Electronic Industries Ltd. 102 POWER+ 3x208 V, User Guide, Release 2.3 2. Select Set Auto Battery Test Period and then press Ent: [Main M
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 103 3. Using the arrow keys, set the battery test top time, and then pr
Gamatronic Electronic Industries Ltd. xii POWER+ 3x208 V User Guide, Release 2.3 Figure 310: A Wing unit connected to the PowerPlus...
Gamatronic Electronic Industries Ltd. 104 POWER+ 3x208 V, User Guide, Release 2.3 8.10.12 Activating ‘Auto’ Test 1. Select ‘AuTo’ Test: [Main Menu
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 105 2. Select ENABLE SHUTDOWN by long AC FAIL (Off) and press Ent to tog
Gamatronic Electronic Industries Ltd. 106 POWER+ 3x208 V, User Guide, Release 2.3 8.11 Setup – Charge, Time, Site, and Password Options SYSTEMMAINME
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 107 8.11.1 Setting the Floating Charge 1. Select Charge: [Main Menu &g
Gamatronic Electronic Industries Ltd. 108 POWER+ 3x208 V, User Guide, Release 2.3 2. Using the arrow keys, set the date and time, and then press Ent
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 109 8.11.4 Changing the Password 1. Select Password #1: [Main Menu >
Gamatronic Electronic Industries Ltd. 110 POWER+ 3x208 V, User Guide, Release 2.3 8.12 “Setup – “Service” Option 2) UPSs4) DryOut Test6) En/Dis sha
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 111 1) # OF UPSs (redundancy)2) # OF UPSs (total)3) # OF BATT4) Static S
Gamatronic Electronic Industries Ltd. 112 POWER+ 3x208 V, User Guide, Release 2.3 2. Select Service: [Main Menu > SETUP > (password) > Ent]
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 113 2. Press ▲ slowly to test each relay, and press Esc when finished:
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 xiii SAFETY CONSIDERATIONS The POWER+ UPS system is designed for indust
Gamatronic Electronic Industries Ltd. 114 POWER+ 3x208 V, User Guide, Release 2.3 8.12.3.2 Total Number of UPSs 1. Select # OF UPSs (total): [Main
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 115 8.12.3.4 Setting up the Static Switch 1. Select Static Switch Setup
Gamatronic Electronic Industries Ltd. 116 POWER+ 3x208 V, User Guide, Release 2.3 8.12.3.5 Setting up the Dry Alarms 1. Select Dry, Alarms: [Main M
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 117 8.12.3.6 Calibrating DC Currents 1. Select Calibration: [Main Menu
Gamatronic Electronic Industries Ltd. 118 POWER+ 3x208 V, User Guide, Release 2.3 5. Press Ent to continue: [Main Menu > SETUP > (password) &g
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 119 8.12.3.8 Enabling/Disabling Remote Commands 1. Select REM COMMAND:
Gamatronic Electronic Industries Ltd. 120 POWER+ 3x208 V, User Guide, Release 2.3 8.12.5 Setting Power Factor Correction 1. Select Powr.Calib: [Mai
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 121 3. Select Factory settings: [Main Menu > SETUP > (password) &
Gamatronic Electronic Industries Ltd. 122 POWER+ 3x208 V, User Guide, Release 2.3 7. Select GATEWAY: [Main Menu > SETUP > (password) > Ent
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 123 11. Select Store: [Main Menu > SETUP > (password) > Ent &g
Gamatronic Electronic Industries Ltd. xiv POWER+ 3x208 V User Guide, Release 2.3 ATTENTION - AVERTISSEMENT - RISQUE DE DÉCHARGE ÉLECTRIQUE MORTELLE
Gamatronic Electronic Industries Ltd. 124 POWER+ 3x208 V, User Guide, Release 2.3 8.13 “Setup – “Silicon” Option Figure 267 :Main Menu option 7 (“
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 125 3. Select Reset Log and then Ent to clear the log: [Main Menu >
Gamatronic Electronic Industries Ltd. 126 POWER+ 3x208 V, User Guide, Release 2.3 6. Select Reset Total Time or Last Maint. Set if needed: [Main Men
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 127 8.14 “Static Switch” option Figure 275: Static switch option 1.
Gamatronic Electronic Industries Ltd. 128 POWER+ 3x208 V, User Guide, Release 2.3 8.15 System Controller Setup Verification The screens described be
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 129 8.15.1 Setup Verification Menu All of the functions listed below ar
Gamatronic Electronic Industries Ltd. 130 POWER+ 3x208 V, User Guide, Release 2.3 8.15.4 Software and Communication Revision The firmware revision r
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 131 8.15.7 Alarms Status Alarms shown as solid circles are active: [3-s
Gamatronic Electronic Industries Ltd. 132 POWER+ 3x208 V, User Guide, Release 2.3 8.15.9.1 First General Screen A description of the various system
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 133 8.15.9.2 Second General Screen From the screen shown in the previou
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 xv AVERTISSEMENT : RISQUE DE DOMMAGES GRAVES À L'UPS
Gamatronic Electronic Industries Ltd. 134 POWER+ 3x208 V, User Guide, Release 2.3 8.15.9.3 Third General Screen From the screen shown in the previou
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 135 9. THE POWER+ BUILT-IN WEB INTERFACE If your Power+ has the remote
Gamatronic Electronic Industries Ltd. 136 POWER+ 3x208 V, User Guide, Release 2.3 Figure 293: Main Screen of the Power+ Web interface 9.2 Main Scr
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 137 9.3 The Main Menu and its options The Main Menu of Power+’s built-i
Gamatronic Electronic Industries Ltd. 138 POWER+ 3x208 V, User Guide, Release 2.3 9.3.1 “Analysis” main menu option The main menu’s “Analysis” optio
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 139 9.3.3 “STSW” (Static Switch) main menu option The “STSW” (Static Sw
Gamatronic Electronic Industries Ltd. 140 POWER+ 3x208 V, User Guide, Release 2.3 9.3.4 “Log” main menu option Figure 297: Listing the log entries
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 141 Table 14: Alarm message text in Web interface log display (Use the
Gamatronic Electronic Industries Ltd. 142 POWER+ 3x208 V, User Guide, Release 2.3 9.3.5 “Control” main menu option The “Control” main menu option en
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 143 Simulate UPS output source on battery: clicking on this link simulat
Gamatronic Electronic Industries Ltd. xvi POWER+ 3x208 V User Guide, Release 2.3
Gamatronic Electronic Industries Ltd. 144 POWER+ 3x208 V, User Guide, Release 2.3 9.3.7 “Configuration” main menu option Choosing the “Configuratio
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 145 9.3.7.1 Network configuration The “Network configuration” option on
Gamatronic Electronic Industries Ltd. 146 POWER+ 3x208 V, User Guide, Release 2.3 9.3.7.3 Set user name and password The “Set user name and password
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 147 9.3.7.4 SNMP security The SNMP security screen is where you define
Gamatronic Electronic Industries Ltd. 148 POWER+ 3x208 V, User Guide, Release 2.3 9.3.7.6 Shutdown Targets The “Shutdown Targets” option of the Conf
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 149 HOW AUTO-SHUTDOWN WORKS: In the event of an ac power mains failure,
Gamatronic Electronic Industries Ltd. 150 POWER+ 3x208 V, User Guide, Release 2.3 9.3.7.7 Defining email notification targets The Web interface enab
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 151 9.3.7.8 Defining SMS notifications The “SMS notifications” option o
Gamatronic Electronic Industries Ltd. 152 POWER+ 3x208 V, User Guide, Release 2.3 10. SNMP AGENT (OPTION) The SNMP agent is an optional, internal ca
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 153 11. WING: WIRELESS CONTROL (OPTION) The POWER+ system includes an
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V User Guide, Release 2.3 1 1. INTRODUCTION Thank you for purchasing a POWER+ UPS system. POWER
Gamatronic Electronic Industries Ltd. 154 POWER+ 3x208 V, User Guide, Release 2.3 Figure 311: Connections between the Power+ controller and the Win
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 155 7. From the Wing home page, navigate to Configuration > SMS noti
Gamatronic Electronic Industries Ltd. 156 POWER+ 3x208 V, User Guide, Release 2.3 Table 19: List of SMS commands
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 157 12. POWER+ SPECIFICATIONS Table 20: Specifications POWER+ TECHNICA
Gamatronic Electronic Industries Ltd. 158 POWER+ 3x208 V, User Guide, Release 2.3 Dimensions (U.S. measurements) UPS type 10 kVA 20 kVA 30 kVA 4
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 159 For a full company profile, please visit out website at www.gamatron
Gamatronic Electronic Industries Ltd. 2 POWER+ 3x208 V, User Guide, Release 2.3 Figure 1: 40 kVA Configuration Figure 2: 100 kVA – Small enough
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 3 The POWER+ is comprised of the following sub-assemblies.
Gamatronic Electronic Industries Ltd. Har Hotzvim Industrial Park 14 Hartom St., PO Box 45029, Jerusalem 91450 Israel Tel: +972-2-588-8222
Gamatronic Electronic Industries Ltd. 4 POWER+ 3x208 V, User Guide, Release 2.3 1.1 System Controller The POWER+ system controller has three purpos
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 5 Please refer to the battery manufacturer’s installation manual for ba
Gamatronic Electronic Industries Ltd. 6 POWER+ 3x208 V, User Guide, Release 2.3 CAUTION: A BATTERY CAN PRESENT A RISK OF ELECTRICAL SHOCK AND HIGH
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 7 ATTENTION N'ouvrez pas ou ne mutilez pas la batterie ou les batt
Gamatronic Electronic Industries Ltd. 8 POWER+ 3x208 V, User Guide, Release 2.3 2. OPERATING MODES The POWER+ UPS functions to supply ac electrical
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 9 2.4 Maintenance Bypass The maintenance bypass switch allows for conne
Gamatronic Electronic Industries Ltd. 10 POWER+ 3x208 V, User Guide, Release 2.3 3. USER INTERFACE This section describes the buttons and indicators
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 11 3.3 Static Switch Panel The static switch panel, located on the fron
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 13 3.5 Navigation and Operation Keypad The navigation and operation key
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 iii TABLE OF CONTENTS SAFETY CONSIDERATIONS...
Gamatronic Electronic Industries Ltd. 14 POWER+ 3x208 V, User Guide, Release 2.3 3.6 Status Indicators The status indicators show precisely what is
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 15 3.7 Operation Buttons The operation buttons illustrated below are “s
Gamatronic Electronic Industries Ltd. 16 POWER+ 3x208 V, User Guide, Release 2.3 3.9 POWER+ Operation Modes 3.9.1 Normal Operation During normal o
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 17 Figure 14: AC power failure indication 3.9.3 Bypass Operation (Aut
Gamatronic Electronic Industries Ltd. 18 POWER+ 3x208 V, User Guide, Release 2.3 Figure 18: UPS in bypass mode indication 3.9.5 Emergency Power O
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 19 4. INSTALLATION PREPARATIONS This is where you begin when preparing
Gamatronic Electronic Industries Ltd. 20 POWER+ 3x208 V, User Guide, Release 2.3 L1 L2 L3 N L1 L2 L3 N L1 L2 L3 AC INPUT BYPASS 3 X 208,
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 21 4.2 Preparation 1. Prepare the proper infrastructure for the POWER+
Gamatronic Electronic Industries Ltd. 22 POWER+ 3x208 V, User Guide, Release 2.3 4.3 The Power+ always requires a neutral line During both installat
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 23 Figure 22: Wrong way to connect UPS with four-pole switch WARNI
Gamatronic Electronic Industries Ltd. iv POWER+ 3x208 V User Guide, Release 2.3 5.10.3 Test Under Load...
Gamatronic Electronic Industries Ltd. 24 POWER+ 3x208 V, User Guide, Release 2.3 Figure 23: Acceptable connection for grounded generator and 4-pole
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 25 Figure 24: Preferred generator (neutralized) and connection (3-po
Gamatronic Electronic Industries Ltd. 26 POWER+ 3x208 V, User Guide, Release 2.3 5. SYSTEM INSTALLATION 5.1 Cabling WARNING! RISK OF ELECTRIC
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 27 Figure 25: Connection diagram for 3-3 configuration
Gamatronic Electronic Industries Ltd. 28 POWER+ 3x208 V, User Guide, Release 2.3 Figure 26: Connection diagram for 3-2 configuration
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 29 Figure 27: Connection diagram for 2-2 configuration
Gamatronic Electronic Industries Ltd. 30 POWER+ 3x208 V, User Guide, Release 2.3 5.2 Over-Voltage Protection CAUTION! To reduce the risk of fire,
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 31 POWER+ MODEL LINE MAXIMUM OVER-CURRENT PROTECTION Load Battery dc
Gamatronic Electronic Industries Ltd. 32 POWER+ 3x208 V, User Guide, Release 2.3 5.3 Fuses WARNING! To reduce the risk of fire, replacement fuse
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 33 5.3.2 DC DISTRIBUTION FUSES Verify that the appropriate dc fuses are
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 v 8.12.4 Enabling/Disabling Current Sharing ...
Gamatronic Electronic Industries Ltd. 34 POWER+ 3x208 V, User Guide, Release 2.3 5.4 Special Terminal Connections This section describes the special
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 35 5.4.2 Special Terminal Connections on 100 kVA Units On the 100 kVA m
Gamatronic Electronic Industries Ltd. 36 POWER+ 3x208 V, User Guide, Release 2.3 5.4.4 Battery Trip Coil The battery trip coil terminals are intende
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 37 5.5 Inspections to be performed prior to installation Table 5: Pre-
Gamatronic Electronic Industries Ltd. 38 POWER+ 3x208 V, User Guide, Release 2.3 5.6 Installation Procedure Table 6: Installation procedure OPERAT
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 39 5.7 First-time Startup This section describes the procedure for star
Gamatronic Electronic Industries Ltd. 40 POWER+ 3x208 V, User Guide, Release 2.3 WAIT FOR RESULTS…STATIC RAM: PASSED R.T CLOCK: PASSEDEEPROM – 1:
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 41 LOAD LEVEL ---11:20:25---L1: _____ 030A, 120V
Gamatronic Electronic Industries Ltd. 42 POWER+ 3x208 V, User Guide, Release 2.3 5.8 Checks to be performed following initial startup Table 7: Post
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 43 5.9 Configuration Perform the following configuration steps from the
Gamatronic Electronic Industries Ltd. vi POWER+ 3x208 V User Guide, Release 2.3 LIST OF FIGURES Figure 1: 40 kVA Configuration ...
Gamatronic Electronic Industries Ltd. 44 POWER+ 3x208 V, User Guide, Release 2.3 5. Select Configure, option 5, to configure the Power+ modules: [Ma
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 45 5.9.2 Check Total Ampere-Hours This procedure is designed to ensure
Gamatronic Electronic Industries Ltd. 46 POWER+ 3x208 V, User Guide, Release 2.3 5.9.3 Set Date and Time and Serial Number To verify the date and ti
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 47 3. Use the arrow keys to set the IP address, and then press Ent: [M
Gamatronic Electronic Industries Ltd. 48 POWER+ 3x208 V, User Guide, Release 2.3 5.10 Testing Perform the following tests on the Power+ unit. 5.10.1
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 49 5.10.4 Check IP Communication with Controller This test is designed
Gamatronic Electronic Industries Ltd. 50 POWER+ 3x208 V, User Guide, Release 2.3 Figure 60: Local Area Connection Properties screen c. When the Lo
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 51 d. When the Internet Protocol (TCP/ITP Properties screen appears, cl
Gamatronic Electronic Industries Ltd. 52 POWER+ 3x208 V, User Guide, Release 2.3 1. Click the Send SMS button on the left sidebar of the Main Screen
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 53 6. POWER+ ROUTINE START-UP This section describes the start-up proce
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 vii Figure 50: Battery status...
Gamatronic Electronic Industries Ltd. 54 POWER+ 3x208 V, User Guide, Release 2.3 If the inverter indicator on the Static Switch panel is OFF: ● Pres
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 55 6.1 POWER+ Shutdown (Switching to Bypass) 1. Switch the load OFF. 2
Gamatronic Electronic Industries Ltd. 56 POWER+ 3x208 V, User Guide, Release 2.3 Figure 73: UPS off indication
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 57 7. POWER+ CONTROL PANEL The POWER+ system is equipped with an LCM di
Gamatronic Electronic Industries Ltd. 58 POWER+ 3x208 V, User Guide, Release 2.3 Quick-Reference Summary of Power+ Menu Functions The following flowc
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 59 Figure 77: Battery menu Figure 78: Setup menu Figure 79: Stat
Gamatronic Electronic Industries Ltd. 60 POWER+ 3x208 V, User Guide, Release 2.3 Figure 80: Alarm set sub-menu Figure 81: Module configuration
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 61 Figure 83: Service sub-menu
Gamatronic Electronic Industries Ltd. 62 POWER+ 3x208 V, User Guide, Release 2.3 Figure 84: Configure sub-sub-menu Figure 85: Silicon sub-menu
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 63 8. POWER+ MENU FUNCTIONS IN DETAIL This chapter describes the functi
Gamatronic Electronic Industries Ltd. viii POWER+ 3x208 V User Guide, Release 2.3 Figure 102: Module phase voltages/currents...
Gamatronic Electronic Industries Ltd. 64 POWER+ 3x208 V, User Guide, Release 2.3 8.2 “System” Option Figure 87: Main menu option 1 ("Syste
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 65 2. View the current output power factors3: [Main Menu > SYSTEM &
Gamatronic Electronic Industries Ltd. 66 POWER+ 3x208 V, User Guide, Release 2.3 6. View the system jumper settings without remote panel: [Main Me
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 67 9. View battery parameters: [Main Menu > SYSTEM > ▼ ▼ ▼ ▼ ▼]
Gamatronic Electronic Industries Ltd. 68 POWER+ 3x208 V, User Guide, Release 2.3 8.3 “UPS module” Option To view voltage and current measurements an
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 69 2. View the input and output voltage and current for each phase of a
Gamatronic Electronic Industries Ltd. 70 POWER+ 3x208 V, User Guide, Release 2.3 8.4 “Self-test” Option You can run a self-test at any time without
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 71 8.5 “History” (logs) Option The last 255 events reserved in the LOG
Gamatronic Electronic Industries Ltd. 72 POWER+ 3x208 V, User Guide, Release 2.3 2. View more details by pressing the ► key. [Main Menu > HISTOR
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 73 Table 9: Log Messages # Message Explanation 01 UPSMAJ More than
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 ix Figure 154: Select a phase to adjust...
Gamatronic Electronic Industries Ltd. 74 POWER+ 3x208 V, User Guide, Release 2.3 # Message Explanation 29 OVLOAD Load current is high 30 UPS-CM
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 75 8.6 “Battery” Option The battery option on the main menu displays in
Gamatronic Electronic Industries Ltd. 76 POWER+ 3x208 V, User Guide, Release 2.3 2. View next automatic equalizing, remaining equalizing time, total
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 77 6. View battery capacity: [Main Menu > BATTERY > ▼> ▼>
Gamatronic Electronic Industries Ltd. 78 POWER+ 3x208 V, User Guide, Release 2.3 8.7 “Alarm” Option Alarms are displayed—there are 32 in all. In add
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 79 2. View alarms 13-24: [Main Menu > ALARM > ▼] 13 – 15 +STSW
Gamatronic Electronic Industries Ltd. 80 POWER+ 3x208 V, User Guide, Release 2.3 8.8 “Setup – Alarm Set” Option MAINMENUOPTIONSSYSTEMUPS MODULESELFT
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 81 2. Select Alarm set: [Main Menu > SETUP > (password) > Ent
Gamatronic Electronic Industries Ltd. 82 POWER+ 3x208 V, User Guide, Release 2.3 4. Select Set AC Alarms Hysteresis: [Main Menu > SETUP > Ent
Gamatronic Electronic Industries Ltd. POWER+ 3x208 V, User Guide, Release 2.3 83 3. Use the arrow keys to set BATEND and press Ent: [Main Menu >