DISCHARGE AIR NOZZLE KIT ASSEMBLY CONDENSATE PUMP KIT A condensate pump kit is designed for automatic condensate removal system for wate
1) Unplug unit. Open lower front door to expose condensate bucket. Remove bucket. airbossmanualpg9a The Quick Connect Condensate Pump may be easily in
CONDENSER INLET AIR PLENUM DCP, Condenser Plenums are used to duct condenser air to the unit. The plenum easily attaches with one screw (supplied) to
EVAPORATOR INLET AIR PLENUM DEP, Evaporator Plenums are used to allow a return air duct to be attached to the unit. The plenum easily attaches with mo
DDA, Duct Adapter is used to apply a single discharge duct to the evaporator. The standard grille is removed and the Adapter is attached with sheet m
UNIT ACCESSORIES airbossmanpg13 This door must be closed during operation or the unit may trip on the high pres-sure switch. Optional Duct Flange
Plug unit in and push FAN button once. This turns the evaporator fan blower on. To turn the blower off, push the FAN button once again. This turns the
APPLICATIONS ROOM AIR CONDITIONER OceanAire AirBoss can be used as a room air condit
REPLACEMENT PROCEDURE FOR PARTS A. FAN MOTORS 1. Remove cabinet's left-hand (when looking at the fr
E. HIGH PRESSURE CONTROL 1. Remove cabinets right hand side panel. 2. Remove flare nut that secures capillary to the refrigeration system high press
PAGE General Description
2. (CAUSE) Thermostat (REMEDY) Examine the control unit for loose wires. Tighten any loose connections. Wait 4-minutes before re-start. 3. (REASON
PROBLEM: INSUFFICIENT COOLING 1. (CAUSE) Insufficient air flow through evaporator coil due to: A. Dirty air filter in unit
PROBLEM: WATER LEAKING FROM PAN 1. (CAUSE) Leaky drain pan (REMEDY) Locate leak and repair pan. 2. (CAUSE) Loose evaporator, drain or condensate pu
2. FILTERS A clogged filter will cause the unit to operate at greatly reduced efficiencies. We recommend that the filter be inspected on a regular ba
MANUAL RE-SET HIGH PRESSURE SWITCH PIPING SCHEMATIC SUCTION LINE DISCHARGE LINE EVAPORATOR BLOWER CONDENSER COIL CAPILLARY TUBES STRAINER A
HIGH PRESSURE SWITCHL2 FOR208/230L1GOceanaire, Inc.AIRBOSS, (AIR COOLED) MODELS MODELS PAC10, 12, 18, 24, 36, 120/1/60 2
HIGH PRESSURE SWITCHL2 FOR208/230L1GOceanaire, Inc. AIRBOSS, (AIR COOLED) MODELS MODELS PAC10, 12, 18, 24, 36, WITH CO
N.C. N.O. OceanAire, Inc. AIRBOSS (AIR COOLED) MODEL PAC3632 208/230 3 PHASE G Y W RH B O RC THERMOSTAT COOLING ONLY C Y G R TERMINAL BLOCK HI-LO FAN
OceanAire, Inc. AIRBOSS (AIR COOLED) MODEL PAC6012 208/230 1 PHASE G Y W RH B O RC THERMOSTAT COOLING C Y G R TERMINAL BLOCK HI-LO FAN SWITCH HIGH
OceanAire, Inc. AIRBOSS (AIR COOLED) MODEL PAC6032 208/230 3 PHASE G Y W RH B O RC THERMOSTAT COOLING C Y G R TERMINAL BLOCK HI-LO FAN SWITCH HIGH
GENERAL DESCRIPTION AIRBOSS SERIES Portable Air-Cooled Air Conditioners are designed to cool an entire area by discharging air through its 9 1/2 x 4
GYWRH BORCCYGR OceanAire, Inc.AIRBOSS (AIR COOLED) MODEL PAC6034 460 VOLT 3 PHASEAugust 1, 2001T1T2T3COMPRESSOR COOLINGTHERMOSTATTERMINA
The Manufacturer (OceanAire, Inc.) warrants to the original owner that the Product will be free from defects in material or workmanship for a period n
NOMENCLATURE P AC 24 1 2
3 Cooling Capacity is total BTU/HR at 80°DB/67°WB high fan speed Time delay fuses/circuit breakers are recommended. EER determine
STANDARD FEATURES SERVICEABILITY All AirBoss Series units are designed with removable panels t
ELECTRONIC THERMOSTAT The electronic thermostat displays room temperature if the cooling system is on. Select the temperature you want by pressing the
CONDENSATE RESERVOIR TANK The OceanAire AirBoss utilizes a 5.0 gallon capacity, polyethylene condensate drain tank, located in the lower, front secti
OPTIONAL FEATURES TREATED EVAPORATOR AND CONDENSER COILS When airborne contaminants are a problem fo